  6. 3M™ Attest™ Rapid Readout Biological Indicator Test Packs for 250°F/121°C Gravity and 270°F/132°C Vacuum Assisted Steam Sterilizers 1296

3M™ Attest™ Rapid Readout Biological Indicator Test Packs for 250°F/121°C Gravity and 270°F/132°C Vacuum Assisted Steam Sterilizers 1296

3M ID 70200690868UPC 50707387236453Catalog Number 1296
  • 3M Attest Rapid Readout Biological Indicator Test Pack that presents a challenge to the sterilization process equivalent to the AAMI recommended towel pack for 121C (250F) Gravity Displacement Cycles and 132C (270F) Vacuum-Assisted cycles. Comes with 25 controls. The pack is specifically designed to present a resistant challenge to the steam sterilization process as does the AAMI 16 towel pack.
  • Self-contained biological indicators significantly reduce possibility of contamination, minimizing false positives and assuring more accurate results.
  • Faster result time, making it possible to quarantine every load and eliminate recalls.
  • System can help reduce the costs associated with fighting infections - cost measured in both dollars and time spent.
 More...
View all details
Specifications
Attribute Name
Value
Biological Indicator System
Rapid
Brand
Attest™
Cap Color
Brown
Catalog Number
1296
Product Type
Biological Indicator
Product Use
Load Monitoring
Sterilisation Method
Steam
Product Details
  • 3M Attest Rapid Readout Biological Indicator Test Pack that presents a challenge to the sterilization process equivalent to the AAMI recommended towel pack for 121C (250F) Gravity Displacement Cycles and 132C (270F) Vacuum-Assisted cycles. Comes with 25 controls. The pack is specifically designed to present a resistant challenge to the steam sterilization process as does the AAMI 16 towel pack.
  • Self-contained biological indicators significantly reduce possibility of contamination, minimizing false positives and assuring more accurate results.
  • Faster result time, making it possible to quarantine every load and eliminate recalls.
  • System can help reduce the costs associated with fighting infections - cost measured in both dollars and time spent.
  • Color-coded for quick reference and easy use.

Rapid Readout Biological Indicator Test Pack for Steam 250(deg)F/121(deg)C gravity displacement or 270(deg)F/132(deg)C vacuum assisted sterilization cycles, Includes 25 test packs brown cap biological indicators only + 25 controls, 3 hour readout, Brown cap

3M Attest Rapid Readout Biological Indicator Test Pack that presents a challenge to the sterilization process equivalent to the AAMI recommended towel pack for 121C (250F) Gravity Displacement Cycles and 132C (270F) Vacuum-Assisted cycles. Comes with 25 controls. The pack is specifically designed to present a resistant challenge to the steam sterilization process as does the AAMI 16 towel pack.

Large Volume Order​

Изпратете ни съобщение

Благодарим ви за интереса към 3M. За да ни помогнете да управляваме и да отговорим ефективно на Вашето запитване, ние учтиво Ви молим да предоставите ключова информация, включително Вашите данни за контакт. Информацията, която предоставяте, ще бъде използвана за отговор на вашата заявка по имейл или телефон от представител на 3M или един от нашите упълномощени бизнес партньори, с които бихме могли да споделим вашата лична информация в съответствие с политиката за поверителност на 3M.

  •  
  •  
  •  
  •  
  •  
  • 3M takes your privacy seriously. 3M and its authorized third parties will use the information you provided in accordance with our Privacy Policy to send you communications which may include promotions, product information and service offers. Please be aware that this information may be stored on a server located in the U.S. If you do not consent to this use of your personal information, please do not use this system.

  • Изпращане на съобщение

Благодарим ви, че се свързахте с 3M

Получихме вашето съобщение и сега разглеждаме запитването ви
Наш представител ще се свърже с вас по телефона или имейл

An error occurred.