  • 3M™ Cold Shrink QT-II Outdoor Termination Kit 5651, JCN Cable, 15-25/28 kV, 16-28 mm Cable Insul. O.D., 1 termination/kit
  • 3M™ Cold Shrink QT-II Outdoor Termination Kit 5651, JCN Cable, 15-25/28 kV, 16-28 mm Cable Insul. O.D., 1 termination/kit

    3M ID 80610252670
    • Cold shrink termination for an easy and secure solution to terminate medium voltage cables up to 25 KV
    • High dielectric-constant material regulates the distribution of electric field stress
    • Suitable for outdoor, weather exposed applications
    • Silicone rubber insulation is track-resistance and hydrophobic
     More...
    View all details
    Product Details

    3M™ Cold Shrink Medium Voltage termination kit QT II series, thanks to the cold shrink silicon insulation body provides an easy and secure solution for MV cable termination.

    • Cold shrink termination for an easy and secure solution to terminate medium voltage cables up to 25 KV
    • High dielectric-constant material regulates the distribution of electric field stress
    • Suitable for outdoor, weather exposed applications
    • Silicone rubber insulation is track-resistance and hydrophobic
    • Silicone cold shrink application provides constant radial pressure, "living seal"
    • Voltage ratings: 4 skirt kits up to 15kV, 110 kV BIL; 6 skirt kits up to 25/28 kV, 150 kV BIL; 8 skirt kits up to 35 kV, 200 kV BIL
    • Meets IEEE Standard 48, Class 1 for outdoor, weather-exposed applications
    Specifications
    Attribute Name
    Value
    Agency Approvals
    IEEE
    Applications
    Cable Termination
    BIL
    150 kV
    Breakout Boot
    No
    Cable Insulation Outside Diameter Range (metric)
    16,2 - 28,5 mm
    Cable Type
    Polymeric insulated, copper wire screened, unarmored cable
    Case Quantity
    1
    Conductor Size by Voltage
    (15 kV) 2-2/0 AWG, (25/28 kV) 2-1/0 AWG
    Conductor Size Range
    25 - 120 mm²
    Conductor Sizes
    1 AWG, 1/0 AWG, 2 AWG, 2/0 AWG
    Family
    QT-II
    Indoor/Outdoor
    Outdoor Skirted
    Insulation Level
    100%, 133%
    Insulation O.D. Range (Metric)
    16.2-28.4 mm
    Insulation Outer Diameter (metric)
    16,256 Millimetre, 16,51 Millimetre, 16,764 Millimetre, 17,018 Millimetre, 17,272 Millimetre, 17,526 Millimetre, 17,78 Millimetre, 18,034 Millimetre, 18,288 Millimetre, 18,542 Millimetre, 18,796 Millimetre, 19,05 Millimetre, 19,304 Millimetre, 19,558 Millimetre, 19,812 Millimetre, 20,066 Millimetre, 20,32 Millimetre, 20,574 Millimetre, 20,828 Millimetre, 21,082 Millimetre, 21,336 Millimetre, 21,59 Millimetre, 21,844 Millimetre, 22,098 Millimetre, 22,352 Millimetre, 22,606 Millimetre, 22,86 Millimetre, 23,114 Millimetre, 23,368 Millimetre, 23,622 Millimetre, 23,876 Millimetre, 24,13 Millimetre, 24,384 Millimetre, 24,638 Millimetre, 24,892 Millimetre, 25,146 Millimetre, 25,4 Millimetre, 25,654 Millimetre, 25,908 Millimetre, 26,162 Millimetre, 26,416 Millimetre, 26,67 Millimetre, 26,924 Millimetre, 27,178 Millimetre, 27,432 Millimetre, 27,686 Millimetre, 27,94 Millimetre, 28,194 Millimetre, 28,448 Millimetre
    Insulation Rejacketing
    No
    Jacket Outside Diameter Range (metric)
    23.6-34.3 mm
    Lug/Stem Connector Included in Kit
    No
    Manufacturing Origin
    USA
    Material
    Silicone Rubber
    Maximum Wire Gauge
    120mm²
    Minimum Wire Gauge
    25mm²
    Number of Conductors
    1
    Number of Skirts
    6
    Product Colour
    Grey
    Product Series
    5650
    Product Technology
    Cold Shrink
    RoHS 2011/65/EU Compliant
    Undetermined
    RoHS EU Comments
    Contact 3M for information
    Shielding Type
    Jacketed Concentric Neutral (JCN)
    Voltage Rating
    12/20 kV