1. Bulgaria
  2. All 3M Products
  3. Medical
  4. Patient Monitoring
  5. Electrodes
  6. 3M™ Red Dot™ Foam Monitoring Electrode 2570, with Sticky Gel and Abrader, Radiolucent, 4 cm x 3.5 cm

3M™ Red Dot™ Foam Monitoring Electrode 2570, with Sticky Gel and Abrader, Radiolucent, 4 cm x 3.5 cm

Catalog Number 25703M ID 70200757238
Discontinued
  • Adhesive foam-tape backing and proprietary sticky gel ensure excellent skin contact
  • Remains fresh for 30 days out of the bag
  • High performance adhesive offers instant adhesion and up to five-day wear with excellent patient skin care and comfort
  • Sticky gel delivers excellent trace quality resulting in better patient information
 More...
View all details
Specifications
Attribute Name
Value
Applications
Intensive
Backing Material
Foam material
Case Packaging
50 Electrodes/Bag; 20 Bags or 1000 Electrodes/Case
Department
Cardiac Rehab, Cath Lab, EMS/ER, ICU/CCU, OR
Electrode Size
1.60" x 1.36"
Electrode Type
Diaphoretic, Fluid Resistant, Monitoring
Gel Type
Sticky
Material
Foam
Model
2570
Monitoring Event
Echo-Cardio, Stress Test, Telemetry/Holter/Event
Overall Length (Metric)
3,5 cm
Overall Width (Metric)
3,5 cm
Patient
Adult
Pre-Wired
No
Product Type
Electrode
Product Type Free Format
Electrode
Product Use
Diaphoretic, Monitoring
Radiolucency
Radiolucent
Skin Prep Included
No
Skin Type
Normal
Solution
Fluid Resistant, Monitoring, Standardization, Value Price
Therapeutic Area and Conditions
Diaphoretic, Holter Monitoring, Multipurpose Electrode, Radiolucent
Wear Time
Up to Five Days
Product Details

Red Dot™ Monitoring Electrode with Foam Tape and Sticky Gel

1.6 inch x 1.36 inch (4cm x 3,5cm) Monitoring Electrode with Foam Tape and Sticky Gel, radiolucent stud, with abrader (50 Each/Bag; 20 Bag/Case)

  • Adhesive foam-tape backing and proprietary sticky gel ensure excellent skin contact
  • Remains fresh for 30 days out of the bag
  • High performance adhesive offers instant adhesion and up to five-day wear with excellent patient skin care and comfort
  • Sticky gel delivers excellent trace quality resulting in better patient information
  • Smaller size electrode is easier to place, and minimizes skin irritation for better patient comfort
  • Conveniently packaged in individual strips of ten electrodes for easy use and less waste

Suggested Applications

  • ECG monitoring
  • For applications requiring high adhesion
  • For hospital-wide use; especially suited for the ER, OR and Catheter Lab or ICU and Paramedics